Door terminal set, DT 210 FH, Dialock for fire resistant/smoke control doors, without thumbturn, Legic®

For interior doors

    • Technical documents available.
      Please select an article to view.

    Filter

    Complete your selection

    Help

    Help

    Requested amount is in stock.
    Limited stock available.
    Item no longer available

    Note:
    To receive items as fast as possible, choose 'when available' at checkout.

    Door terminal set, DT 210 FH, Dialock for fire resistant/smoke control doors, without thumbturn, Legic®

    For interior doors

    • Backplate exterior module with processor

    • Backplate interior module

    Image may show a similar article, please check product details.

    Door terminal set, DT 210 FH, Dialock for fire resistant/smoke control doors, without thumbturn, Legic®

    For interior doors, U-shape lever handle square, satin stainless steel, with lever handle pointing to the left

    Art. no. 917.34.883

    Door terminal set, DT 210 FH, Dialock for fire resistant/smoke control doors, without thumbturn, Legic®

    For interior doors, L-shape lever handle square, satin stainless steel, with lever handle pointing to the left

    Art. no. 917.34.884

    Door terminal set, DT 210 FH, Dialock for fire resistant/smoke control doors, without thumbturn, Legic®

    For interior doors, U-shape lever handle square, stainless steel polished brass plated (PVD), with lever handle pointing to the left

    Art. no. 917.34.885

    Door terminal set, DT 210 FH, Dialock for fire resistant/smoke control doors, without thumbturn, Legic®

    For interior doors, L-shape lever handle square, stainless steel polished brass plated (PVD), with lever handle pointing to the left

    Art. no. 917.34.887

    Door terminal set, DT 210 FH, Dialock for fire resistant/smoke control doors, without thumbturn, Legic®

    For interior doors, U-shape lever handle square, satin stainless steel, with lever handle pointing to the right

    Art. no. 917.34.893
    Product details

    Area of application

    Interior doors, Offices in the Back-Office, Doors with fire/smoke protection requirements

    Distance

    72 mm

    Door thickness

    38 – 98 mm

    Area of application

    for doors with requirements on fire resistance and smoke control

    Transponder technology

    Legic®

    Functionality

    battery-operated, intelligent door terminal, contactless activation using Dialock key
    - identical design to DT 210 for interior guest room doors, but without rotary knob for "Do not disturb" indication
    - Indication of unlocking and locking with blue/red LEDs
    - Standard setting: Unlocking with Dialock key and automatic locking after 3 seconds
    - The door can be opened from the inside without a key at any time
    - electronic and mechanical emergency opening is possible
    - for service personnel: Indication of programming status and when battery change is required
    - Unlocking and locking with Dialock key (toggle mode)
    - with real-time clock and logging of all procedures, including electronic emergency openings
    - Infrared interface for programming

    Options

    Front foil with customised design, Macros for extension of functions available on request, Audit trail of mechanical emergency openings via mortise lock with feedback

    Material

    Stainless steel

    Order reference

    Please order supplementary and optional components, e.g. lever handle aperture parts, mounting material for other door thicknesses and batteries, separately.
    The minimum order quantity of DT 210 door terminals with polished brass plated (PVD) finish is 10 door terminals per order.

    Supplied with

    1 R2 exterior module with processor
    1 R2 interior module
    2 lever handle aperture parts
    Mounting material (e.g. spindle, threaded screw)

    Additional information attributes

    Notes on operation and installation

    Planning by Dialock specialist is required.
    DT 210 FH door terminal sets must be installed by Dialock specialists after approval by the door manufacturer. Otherwise the Fire and Smoke Control Certificate for the door will be invalidated.

    Only to be used in combination with Dialock DIN mortice locks for fire resistant and smoke control doors.

    Mechanical emergency opening
    DT 210 FH door terminal sets must always be equipped with a single profile cylinder for mechanical emergency opening.
    When using the mechanical emergency opening, please note the information sheet for determining the length of the single profile cylinder (operating instructions can be found in our online shop).

    Battery change:
    The type-specific discharge behaviour (steep drop in voltage at the end of the life time) of lithium batteries can lead to the battery due date only being displayed on the terminal for a short period or not at all.

    Corporate Office: Häfele America Co., 3901 Cheyenne Drive, Archdale, N.C. 27263
    Phone: 800.423.3531, Fax: 800.325.6197, Local Phone: 336.434.2322, Email: info@haefeleamericas.com
    09-Aug-2022